Structure:
Corrugated Aluminum Sheath
Voltage:
38/66kV, 64/110kV, 76/132kV, 127/220kV
Conductor:
Copper/Aluminum Class 2
Core:
single core
Cross Sectional Area:
240mm2~2500mm2
Insulation:
XLPE
Inner Sheath:
Aluminum Sheath
Outer Sheath:
PE (or PVC)
Lead Sheath
· Voltage:
38/66kV, 64/110kV, 76/132kV, 127/220kV
· Conductor:
Copper/Aluminum Class 2
· Core:
single core
· Cross Sectional Area:
240mm2~2500mm2
· Insulation:
XLPE
· Inner Sheath:
Lead Sheath
· Outer Sheath:
PE (or PVC)
Copper Wire Shield
· Voltage:
38/66kV, 64/110kV, 76/132kV, 127/220kV
· Conductor:
Copper/Aluminum Class 2
· Core:
single core
· Cross Sectional Area:
240mm2~2500mm2
· Insulation:
XLPE
· Screen:
Copper Wire Screen
· Outer Sheath:
PE (or PVC)
Application:
High voltage cables are commonly used for applications such as interconnection between transmission lines, underground distribution systems and substations.
Feature:
The construction of cables varies depending on the voltage level and the specific application.
For lower voltage levels, the cable consists of solid or stranded conductors with multiple layers of insulation and protective material added around them.
For higher voltage applications, additional layers of insulation and shielding are added to improve the electrical performance and safety of the cable.
Specification:
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
95 | 1.8 | 2.4 | 51 | 4.4 | 5.3 | 0.15 |
120 | 1.8 | 2.5 | 53 | 4.8 | 5.9 | 0.16 |
150 | 1.8 | 2.6 | 55 | 5.2 | 6.5 | 0.16 |
185 | 1.8 | 2.6 | 57 | 5.7 | 7.3 | 0.18 |
240 | 1.9 | 2.7 | 60 | 6.5 | 8.5 | 0.19 |
300 | 1.9 | 2.8 | 62 | 7.2 | 9.2 | 0.2 |
400 | 2 | 3 | 66 | 8.1 | 10.4 | 0.22 |
500 | 2.1 | 3 | 69 | 8.9 | 11.9 | 0.24 |
630 | 2.2 | 3.1 | 73 | 9.9 | 13.6 | 0.26 |
800 | 2.3 | 3.3 | 78 | 11 | 15.9 | 0.29 |
1000 | 2.4 | 3.4 | 81 | 12.2 | 18.2 | 0.31 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
150 | 1.5 | 2.8 | 74 | 3.9 | 4.8 | 0.13 |
185 | 1.6 | 2.9 | 76 | 4.2 | 4.8 | 0.14 |
240 | 1.8 | 3 | 79 | 4.7 | 6.1 | 0.15 |
300 | 1.7 | 3 | 81 | 5 | 6.7 | 0.16 |
400 | 1.7 | 3.1 | 84 | 5.5 | 7.7 | 0.17 |
500 | 1.7 | 3.2 | 88 | 6 | 8.9 | 0.18 |
630 | 1.8 | 3.3 | 92 | 6.8 | 10.5 | 0.2 |
800 | 1.8 | 3.5 | 97 | 7.6 | 12.4 | 0.22 |
1000 | 1.9 | 3.6 | 102 | 8.6 | 14.5 | 0.23 |
1200 | 2 | 3.7 | 110 | 10 | 17.3 | 0.26 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
240 | 1.7 | 3.1 | 84 | 5.2 | 6.6 | 0.14 |
300 | 1.7 | 3.2 | 86 | 5.5 | 7.3 | 0.15 |
400 | 1.7 | 3.3 | 90 | 6 | 8.3 | 0.16 |
500 | 1.8 | 3.4 | 93 | 6.7 | 9.6 | 0.17 |
630 | 1.8 | 3.5 | 97 | 7.4 | 11.1 | 0.18 |
800 | 1.9 | 3.6 | 102 | 8.4 | 13.1 | 0.2 |
1000 | 2 | 3.8 | 107 | 9.4 | 15.3 | 0.22 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
400 | 2 | 3.8 | 108 | 8.5 | 10.8 | 0.13 |
500 | 2.1 | 3.9 | 112 | 9.3 | 12.2 | 0.14 |
630 | 2.1 | 4 | 116 | 10.1 | 13.8 | 0.15 |
800 | 2.2 | 4.1 | 121 | 11.2 | 16 | 0.16 |
1000 | 2.3 | 4.3 | 126 | 12.3 | 18.3 | 0.17 |
1200 | 2.3 | 4.4 | 132 | 13.7 | 20.9 | 0.19 |
1400 | 2.4 | 4.5 | 137 | 14.9 | 23.2 | 0.2 |
1600 | 2.5 | 4.6 | 141 | 16.1 | 25.5 | 0.21 |
2000 | 2.6 | 4.8 | 149 | 18.2 | 30.1 | 0.23 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
95 | 1.8 | 2.4 | 51 | 4.4 | 5.3 | 0.15 |
120 | 1.8 | 2.5 | 53 | 4.8 | 5.9 | 0.16 |
150 | 1.8 | 2.6 | 55 | 5.2 | 6.5 | 0.16 |
185 | 1.8 | 2.6 | 57 | 5.7 | 7.3 | 0.18 |
240 | 1.9 | 2.7 | 60 | 6.5 | 8.5 | 0.19 |
300 | 1.9 | 2.8 | 62 | 7.2 | 9.2 | 0.2 |
400 | 2 | 3 | 66 | 8.1 | 10.4 | 0.22 |
500 | 2.1 | 3 | 69 | 8.9 | 11.9 | 0.24 |
630 | 2.2 | 3.1 | 73 | 9.9 | 13.6 | 0.26 |
800 | 2.3 | 3.3 | 78 | 11 | 15.9 | 0.29 |
1000 | 2.4 | 3.4 | 81 | 12.2 | 18.2 | 0.31 |
1200 | 2.5 | 3.5 | 89 | 14 | 21.3 | 0.36 |
1400 | 2.6 | 3.6 | 93 | 15.3 | 23.6 | 0.38 |
1600 | 2.7 | 3.8 | 97 | 16.5 | 26 | 0.4 |
2000 | 2.9 | 3.9 | 103 | 19.1 | 31 | 0.44 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
150 | 2.1 | 2.9 | 66 | 7.1 | 8.4 | 0.13 |
185 | 2.1 | 3 | 68 | 7.6 | 9.3 | 0.14 |
240 | 1.9 | 2.7 | 60 | 6.5 | 8.5 | 0.19 |
300 | 1.9 | 2.8 | 62 | 7.2 | 9.2 | 0.2 |
400 | 2 | 3 | 66 | 8.1 | 10.4 | 0.22 |
500 | 2.1 | 3 | 69 | 8.9 | 11.9 | 0.24 |
630 | 2.2 | 3.1 | 73 | 9.9 | 13.6 | 0.26 |
800 | 2.3 | 3.3 | 78 | 11 | 15.9 | 0.29 |
1000 | 2.4 | 3.4 | 81 | 12.2 | 18.2 | 0.31 |
1200 | 2.5 | 3.5 | 89 | 14 | 21.3 | 0.36 |
1400 | 2.6 | 3.6 | 93 | 15.3 | 23.6 | 0.38 |
1600 | 2.7 | 3.8 | 97 | 16.5 | 26 | 0.4 |
2000 | 2.9 | 3.9 | 103 | 19.1 | 31 | 0.44 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
400 | 2.9 | 4 | 99 | 15.9 | 18.3 | 0.13 |
500 | 2.9 | 4.1 | 103 | 16.9 | 19.9 | 0.14 |
630 | 3 | 4.2 | 106 | 18.2 | 22 | 0.15 |
800 | 3.1 | 4.3 | 110 | 19.7 | 24.6 | 0.16 |
1000 | 3.3 | 4.4 | 115 | 21.6 | 27.6 | 0.17 |
1200 | 3.4 | 4.6 | 121 | 23.7 | 31 | 0.19 |
1400 | 3.5 | 4.7 | 125 | 25.4 | 33.7 | 0.2 |
1600 | 3.5 | 4.8 | 128 | 26.5 | 36 | 0.21 |
2000 | 3.7 | 5 | 135 | 29.7 | 41.6 | 0.23 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
400 | 2 | 3.8 | 108 | 8.5 | 10.8 | 0.13 |
500 | 2.1 | 3.9 | 112 | 9.3 | 12.2 | 0.14 |
630 | 2.1 | 4 | 116 | 10.1 | 13.8 | 0.15 |
800 | 2.2 | 4.1 | 121 | 11.2 | 16 | 0.16 |
1000 | 2.3 | 4.3 | 126 | 12.3 | 18.3 | 0.17 |
1200 | 2.3 | 4.4 | 132 | 13.7 | 20.9 | 0.19 |
1400 | 2.4 | 4.5 | 137 | 14.9 | 23.2 | 0.2 |
1600 | 2.5 | 4.6 | 141 | 16.1 | 25.5 | 0.21 |
2000 | 2.6 | 4.8 | 149 | 18.2 | 30.1 | 0.23 |
Nominal Area | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | kg/m | kg/m | μF/km |
95 | 2.3 | 48 | 2.2 | 3 | 0.15 |
120 | 2.4 | 50 | 2.5 | 3.5 | 0.16 |
150 | 2.4 | 51 | 2.8 | 4.1 | 0.16 |
185 | 2.5 | 53 | 3.1 | 4.8 | 0.18 |
240 | 2.6 | 56 | 3.7 | 5.7 | 0.19 |
300 | 2.7 | 59 | 4.3 | 6.3 | 0.2 |
400 | 2.8 | 62 | 4.9 | 7.1 | 0.22 |
500 | 2.9 | 65 | 5.3 | 8.2 | 0.24 |
630 | 3 | 69 | 5.9 | 9.6 | 0.26 |
800 | 3.2 | 73 | 6.6 | 11.3 | 0.29 |
1000 | 3.3 | 77 | 7.3 | 13.2 | 0.31 |
1200 | 3.4 | 84 | 8.4 | 15.6 | 0.36 |
1400 | 3.5 | 89 | 9.2 | 17.4 | 0.38 |
1600 | 3.6 | 92 | 9.8 | 19.3 | 0.4 |
2000 | 3.8 | 99 | 11.3 | 23.2 | 0.44 |
Nominal Area | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | kg/m | kg/m | μF/km |
150 | 2.8 | 63 | 3.6 | 4.9 | 0.13 |
185 | 2.9 | 64 | 4 | 5.6 | 0.14 |
240 | 2.9 | 67 | 4.6 | 6.6 | 0.15 |
300 | 3.1 | 70 | 5.3 | 7.2 | 0.16 |
400 | 3.2 | 73 | 5.9 | 8.1 | 0.17 |
500 | 3.3 | 76 | 6.4 | 9.3 | 0.18 |
630 | 3.4 | 80 | 7 | 10.7 | 0.2 |
800 | 3.5 | 84 | 7.7 | 12.5 | 0.22 |
1000 | 3.6 | 88 | 8.5 | 14.4 | 0.23 |
Nominal Area | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | kg/m | kg/m | μF/km |
240 | 3.1 | 72 | 5 | 7 | 0.14 |
300 | 3.2 | 74 | 5.7 | 7.6 | 0.15 |
400 | 3.3 | 78 | 6.3 | 8.6 | 0.16 |
500 | 3.4 | 81 | 6.8 | 9.7 | 0.17 |
630 | 3.5 | 85 | 7.5 | 11.2 | 0.18 |
800 | 3.7 | 89 | 8.3 | 13 | 0.2 |
1000 | 3.8 | 93 | 9.1 | 15 | 0.22 |
1200 | 3.9 | 100 | 10.3 | 17.5 | 0.24 |
Nominal Area | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | kg/m | kg/m | μF/km |
400 | 3.9 | 94 | 8.7 | 11 | 0.13 |
500 | 3.9 | 97 | 9.3 | 12.2 | 0.14 |
630 | 4.1 | 101 | 10 | 13.8 | 0.15 |
800 | 4.2 | 105 | 10.9 | 15.7 | 0.16 |
1000 | 4.3 | 109 | 11.8 | 17.7 | 0.17 |
1200 | 4.4 | 115 | 13 | 20.3 | 0.19 |
1400 | 4.5 | 120 | 13.9 | 22.2 | 0.2 |
1600 | 4.6 | 123 | 14.8 | 24.2 | 0.21 |
2000 | 4.8 | 130 | 16.5 | 28.4 | 0.23 |
Structure:
Corrugated Aluminum Sheath
Voltage:
38/66kV, 64/110kV, 76/132kV, 127/220kV
Conductor:
Copper/Aluminum Class 2
Core:
single core
Cross Sectional Area:
240mm2~2500mm2
Insulation:
XLPE
Inner Sheath:
Aluminum Sheath
Outer Sheath:
PE (or PVC)
Lead Sheath
· Voltage:
38/66kV, 64/110kV, 76/132kV, 127/220kV
· Conductor:
Copper/Aluminum Class 2
· Core:
single core
· Cross Sectional Area:
240mm2~2500mm2
· Insulation:
XLPE
· Inner Sheath:
Lead Sheath
· Outer Sheath:
PE (or PVC)
Copper Wire Shield
· Voltage:
38/66kV, 64/110kV, 76/132kV, 127/220kV
· Conductor:
Copper/Aluminum Class 2
· Core:
single core
· Cross Sectional Area:
240mm2~2500mm2
· Insulation:
XLPE
· Screen:
Copper Wire Screen
· Outer Sheath:
PE (or PVC)
Application:
High voltage cables are commonly used for applications such as interconnection between transmission lines, underground distribution systems and substations.
Feature:
The construction of cables varies depending on the voltage level and the specific application.
For lower voltage levels, the cable consists of solid or stranded conductors with multiple layers of insulation and protective material added around them.
For higher voltage applications, additional layers of insulation and shielding are added to improve the electrical performance and safety of the cable.
Specification:
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
95 | 1.8 | 2.4 | 51 | 4.4 | 5.3 | 0.15 |
120 | 1.8 | 2.5 | 53 | 4.8 | 5.9 | 0.16 |
150 | 1.8 | 2.6 | 55 | 5.2 | 6.5 | 0.16 |
185 | 1.8 | 2.6 | 57 | 5.7 | 7.3 | 0.18 |
240 | 1.9 | 2.7 | 60 | 6.5 | 8.5 | 0.19 |
300 | 1.9 | 2.8 | 62 | 7.2 | 9.2 | 0.2 |
400 | 2 | 3 | 66 | 8.1 | 10.4 | 0.22 |
500 | 2.1 | 3 | 69 | 8.9 | 11.9 | 0.24 |
630 | 2.2 | 3.1 | 73 | 9.9 | 13.6 | 0.26 |
800 | 2.3 | 3.3 | 78 | 11 | 15.9 | 0.29 |
1000 | 2.4 | 3.4 | 81 | 12.2 | 18.2 | 0.31 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
150 | 1.5 | 2.8 | 74 | 3.9 | 4.8 | 0.13 |
185 | 1.6 | 2.9 | 76 | 4.2 | 4.8 | 0.14 |
240 | 1.8 | 3 | 79 | 4.7 | 6.1 | 0.15 |
300 | 1.7 | 3 | 81 | 5 | 6.7 | 0.16 |
400 | 1.7 | 3.1 | 84 | 5.5 | 7.7 | 0.17 |
500 | 1.7 | 3.2 | 88 | 6 | 8.9 | 0.18 |
630 | 1.8 | 3.3 | 92 | 6.8 | 10.5 | 0.2 |
800 | 1.8 | 3.5 | 97 | 7.6 | 12.4 | 0.22 |
1000 | 1.9 | 3.6 | 102 | 8.6 | 14.5 | 0.23 |
1200 | 2 | 3.7 | 110 | 10 | 17.3 | 0.26 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
240 | 1.7 | 3.1 | 84 | 5.2 | 6.6 | 0.14 |
300 | 1.7 | 3.2 | 86 | 5.5 | 7.3 | 0.15 |
400 | 1.7 | 3.3 | 90 | 6 | 8.3 | 0.16 |
500 | 1.8 | 3.4 | 93 | 6.7 | 9.6 | 0.17 |
630 | 1.8 | 3.5 | 97 | 7.4 | 11.1 | 0.18 |
800 | 1.9 | 3.6 | 102 | 8.4 | 13.1 | 0.2 |
1000 | 2 | 3.8 | 107 | 9.4 | 15.3 | 0.22 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
400 | 2 | 3.8 | 108 | 8.5 | 10.8 | 0.13 |
500 | 2.1 | 3.9 | 112 | 9.3 | 12.2 | 0.14 |
630 | 2.1 | 4 | 116 | 10.1 | 13.8 | 0.15 |
800 | 2.2 | 4.1 | 121 | 11.2 | 16 | 0.16 |
1000 | 2.3 | 4.3 | 126 | 12.3 | 18.3 | 0.17 |
1200 | 2.3 | 4.4 | 132 | 13.7 | 20.9 | 0.19 |
1400 | 2.4 | 4.5 | 137 | 14.9 | 23.2 | 0.2 |
1600 | 2.5 | 4.6 | 141 | 16.1 | 25.5 | 0.21 |
2000 | 2.6 | 4.8 | 149 | 18.2 | 30.1 | 0.23 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
95 | 1.8 | 2.4 | 51 | 4.4 | 5.3 | 0.15 |
120 | 1.8 | 2.5 | 53 | 4.8 | 5.9 | 0.16 |
150 | 1.8 | 2.6 | 55 | 5.2 | 6.5 | 0.16 |
185 | 1.8 | 2.6 | 57 | 5.7 | 7.3 | 0.18 |
240 | 1.9 | 2.7 | 60 | 6.5 | 8.5 | 0.19 |
300 | 1.9 | 2.8 | 62 | 7.2 | 9.2 | 0.2 |
400 | 2 | 3 | 66 | 8.1 | 10.4 | 0.22 |
500 | 2.1 | 3 | 69 | 8.9 | 11.9 | 0.24 |
630 | 2.2 | 3.1 | 73 | 9.9 | 13.6 | 0.26 |
800 | 2.3 | 3.3 | 78 | 11 | 15.9 | 0.29 |
1000 | 2.4 | 3.4 | 81 | 12.2 | 18.2 | 0.31 |
1200 | 2.5 | 3.5 | 89 | 14 | 21.3 | 0.36 |
1400 | 2.6 | 3.6 | 93 | 15.3 | 23.6 | 0.38 |
1600 | 2.7 | 3.8 | 97 | 16.5 | 26 | 0.4 |
2000 | 2.9 | 3.9 | 103 | 19.1 | 31 | 0.44 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
150 | 2.1 | 2.9 | 66 | 7.1 | 8.4 | 0.13 |
185 | 2.1 | 3 | 68 | 7.6 | 9.3 | 0.14 |
240 | 1.9 | 2.7 | 60 | 6.5 | 8.5 | 0.19 |
300 | 1.9 | 2.8 | 62 | 7.2 | 9.2 | 0.2 |
400 | 2 | 3 | 66 | 8.1 | 10.4 | 0.22 |
500 | 2.1 | 3 | 69 | 8.9 | 11.9 | 0.24 |
630 | 2.2 | 3.1 | 73 | 9.9 | 13.6 | 0.26 |
800 | 2.3 | 3.3 | 78 | 11 | 15.9 | 0.29 |
1000 | 2.4 | 3.4 | 81 | 12.2 | 18.2 | 0.31 |
1200 | 2.5 | 3.5 | 89 | 14 | 21.3 | 0.36 |
1400 | 2.6 | 3.6 | 93 | 15.3 | 23.6 | 0.38 |
1600 | 2.7 | 3.8 | 97 | 16.5 | 26 | 0.4 |
2000 | 2.9 | 3.9 | 103 | 19.1 | 31 | 0.44 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
400 | 2.9 | 4 | 99 | 15.9 | 18.3 | 0.13 |
500 | 2.9 | 4.1 | 103 | 16.9 | 19.9 | 0.14 |
630 | 3 | 4.2 | 106 | 18.2 | 22 | 0.15 |
800 | 3.1 | 4.3 | 110 | 19.7 | 24.6 | 0.16 |
1000 | 3.3 | 4.4 | 115 | 21.6 | 27.6 | 0.17 |
1200 | 3.4 | 4.6 | 121 | 23.7 | 31 | 0.19 |
1400 | 3.5 | 4.7 | 125 | 25.4 | 33.7 | 0.2 |
1600 | 3.5 | 4.8 | 128 | 26.5 | 36 | 0.21 |
2000 | 3.7 | 5 | 135 | 29.7 | 41.6 | 0.23 |
Nominal Area | Alu. sheath thickness (Minimum) | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | mm | kg/m | kg/m | μF/km |
400 | 2 | 3.8 | 108 | 8.5 | 10.8 | 0.13 |
500 | 2.1 | 3.9 | 112 | 9.3 | 12.2 | 0.14 |
630 | 2.1 | 4 | 116 | 10.1 | 13.8 | 0.15 |
800 | 2.2 | 4.1 | 121 | 11.2 | 16 | 0.16 |
1000 | 2.3 | 4.3 | 126 | 12.3 | 18.3 | 0.17 |
1200 | 2.3 | 4.4 | 132 | 13.7 | 20.9 | 0.19 |
1400 | 2.4 | 4.5 | 137 | 14.9 | 23.2 | 0.2 |
1600 | 2.5 | 4.6 | 141 | 16.1 | 25.5 | 0.21 |
2000 | 2.6 | 4.8 | 149 | 18.2 | 30.1 | 0.23 |
Nominal Area | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | kg/m | kg/m | μF/km |
95 | 2.3 | 48 | 2.2 | 3 | 0.15 |
120 | 2.4 | 50 | 2.5 | 3.5 | 0.16 |
150 | 2.4 | 51 | 2.8 | 4.1 | 0.16 |
185 | 2.5 | 53 | 3.1 | 4.8 | 0.18 |
240 | 2.6 | 56 | 3.7 | 5.7 | 0.19 |
300 | 2.7 | 59 | 4.3 | 6.3 | 0.2 |
400 | 2.8 | 62 | 4.9 | 7.1 | 0.22 |
500 | 2.9 | 65 | 5.3 | 8.2 | 0.24 |
630 | 3 | 69 | 5.9 | 9.6 | 0.26 |
800 | 3.2 | 73 | 6.6 | 11.3 | 0.29 |
1000 | 3.3 | 77 | 7.3 | 13.2 | 0.31 |
1200 | 3.4 | 84 | 8.4 | 15.6 | 0.36 |
1400 | 3.5 | 89 | 9.2 | 17.4 | 0.38 |
1600 | 3.6 | 92 | 9.8 | 19.3 | 0.4 |
2000 | 3.8 | 99 | 11.3 | 23.2 | 0.44 |
Nominal Area | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | kg/m | kg/m | μF/km |
150 | 2.8 | 63 | 3.6 | 4.9 | 0.13 |
185 | 2.9 | 64 | 4 | 5.6 | 0.14 |
240 | 2.9 | 67 | 4.6 | 6.6 | 0.15 |
300 | 3.1 | 70 | 5.3 | 7.2 | 0.16 |
400 | 3.2 | 73 | 5.9 | 8.1 | 0.17 |
500 | 3.3 | 76 | 6.4 | 9.3 | 0.18 |
630 | 3.4 | 80 | 7 | 10.7 | 0.2 |
800 | 3.5 | 84 | 7.7 | 12.5 | 0.22 |
1000 | 3.6 | 88 | 8.5 | 14.4 | 0.23 |
Nominal Area | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | kg/m | kg/m | μF/km |
240 | 3.1 | 72 | 5 | 7 | 0.14 |
300 | 3.2 | 74 | 5.7 | 7.6 | 0.15 |
400 | 3.3 | 78 | 6.3 | 8.6 | 0.16 |
500 | 3.4 | 81 | 6.8 | 9.7 | 0.17 |
630 | 3.5 | 85 | 7.5 | 11.2 | 0.18 |
800 | 3.7 | 89 | 8.3 | 13 | 0.2 |
1000 | 3.8 | 93 | 9.1 | 15 | 0.22 |
1200 | 3.9 | 100 | 10.3 | 17.5 | 0.24 |
Nominal Area | Outer sheath thickness (Nominal) | Overall Diameter (Approx.) | App. Weight (Aluminium) | App. Weight (Copper) | Approx. Capacitance |
mm2 | mm | mm | kg/m | kg/m | μF/km |
400 | 3.9 | 94 | 8.7 | 11 | 0.13 |
500 | 3.9 | 97 | 9.3 | 12.2 | 0.14 |
630 | 4.1 | 101 | 10 | 13.8 | 0.15 |
800 | 4.2 | 105 | 10.9 | 15.7 | 0.16 |
1000 | 4.3 | 109 | 11.8 | 17.7 | 0.17 |
1200 | 4.4 | 115 | 13 | 20.3 | 0.19 |
1400 | 4.5 | 120 | 13.9 | 22.2 | 0.2 |
1600 | 4.6 | 123 | 14.8 | 24.2 | 0.21 |
2000 | 4.8 | 130 | 16.5 | 28.4 | 0.23 |
1. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
2.What can you buy from us?
Wires,Cables ,Cable Assemblies,Cable Trays&Condiut pipe.
3.Can I get a free sample?
Sure,we offer free sample,you only pay the freight.
4.Payment
Our payment term is usually T/T 30% in advanced, the balance before picking up the goods.L/C,PayPal,Western Union are also acceptable.
1. How can we guarantee quality?
Always a pre-production sample before mass production;
Always final Inspection before shipment;
2.What can you buy from us?
Wires,Cables ,Cable Assemblies,Cable Trays&Condiut pipe.
3.Can I get a free sample?
Sure,we offer free sample,you only pay the freight.
4.Payment
Our payment term is usually T/T 30% in advanced, the balance before picking up the goods.L/C,PayPal,Western Union are also acceptable.